NSTX Center Stack Upgrade Calculations (NSTXU)
|
|
Design Point
Basis Information Design
Point Basis Memo
|
|
NSTXU Final Design Review
Calculation Summary (June 2011)
|
|
NSTXU Structural Design
Criteria (January 2016)
|
|
NOTE: Original NSTX Project Calculations found at:
http://nstx.pppl.gov/nstx/Engineering/NSTX_Eng_Site/Technical/General/Calculations/NSTX_Engr_Calcs.html
|
|
WBS
|
WAF's
|
Originator
|
Calculation Number/Revision
|
Subject
|
Finalized?
|
Proposed Reviewer(s)
|
Ready for FDR?
|
Analysis Files
|
Analysis Files
|
1 - Torus
Systems
|
|
|
|
|
|
|
|
Computer
|
Folder
|
Global Model - Description,
Mesh Generation, and Results
|
1000 & 1206
|
Titus
|
NSTXU-CALC-10-01-02
(Was formerly
NSTXU-CALC 13-01-01)
NSTXU-CALC-10-01-03
DRAFT
|
Global Model - Description, Mesh Generation, and Results --
- Torques
to Lids & TF Teeth
- Legs
& Brace Hilti's
- Full
Load Inventory
- Pedistal Loads
|
YES -
APPROVED
|
Zhang
|
YES
|
ptitus-64lt1.pppl.gov
|
c:\nstx\csu\global
|
Seismic Analysis
|
|
Titus
|
NSTXU-CALC-10-02-00
NSTXU-CALC-10-02-01 DRAFT
|
Calculate the
response of the NSTX upgrade to a a seismic
event and qualify the NSTX upgrade tokamak to the standards set for the
project by the DOE
|
YES -
APPROVED
|
Dahlgren
|
YES
|
ptitus-64lt1.pppl.gov
|
c:\nstx\csu\seismic
|
Design Point Spreadsheet
|
|
Neumeyer
|
NSTXU-CALC-10-03-00
Spreadsheet updated
link
|
This calculation provides a
self-consistent description of the "design point" of the NSTX
Center Stack Upgrade, including physical dimensions of major features and
characteristics and ratings of major components.
|
YES - APPROVED
|
Various People
|
YES
|
|
|
Bake-Out Evaluations
|
|
Titus/Zhang/ Brooks/ Jurczynski
|
NSTXU-CALC-10-04-00
|
The purpose of this calculation
is to evaluate bake-out strategies for NSTX upgrade that will produce
acceptable temperatures at the tile surfaces (i.e. temperature approaching
350C and not damage insulation or structural components, particularly near
the PF1B mandrel/case.
|
YES - APPROVED
|
Various People
|
YES
|
|
|
Instrumentation Results
Evaluation
|
|
Titus
|
NSTXU-CALC-10-05-00
DRAFT
|
The
benchmark instrumentation will produce data that will be evaluated after a shot
is complete. The results will then be compared with the DCPS algorithm
predicted values. It is the purpose of this calculation to evaluate the
instrumentation data as it becomes available.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
11- Plasma Facing
Components
|
|
|
|
|
|
|
|
|
|
First Wall Heat
Balance
|
1206 & 3200
|
Brooks
|
NSTXU-CALC-11-01-00
|
Heat Balance -- Includes:
- Size of Cooling Capabilities
- Divertor Tile Thermal Stresses
|
YES -
APPROVED
|
Zhang
|
YES
|
abrooks-64pc1.pppl.gov
|
E:\ANSYS8\NSTX CSU\IBD_OBD ATJ Tiles\121213
|
First Wall General Tile Program
|
1001
|
Boales
|
NSTXU-CALC-11-02-00
=> SUPERSEDED BY CALCS
11-03 & 11-04
|
General Tile Program -- Inlcudes:
- Inner CS Casing Tile Stress
|
|
|
|
|
|
First Wall Final Tile Stress Analyses (ATJ Tiles)
|
1001
|
Tresemer
|
NSTXU-CALC-11-03-00
NSTXU-CALC-11-03-01
|
Stress
Analysis of the ATJ Tiles and Supports
|
YES - APPROVED
|
Myatt
|
YES
|
|
|
Fastener Analysis
|
1001
|
Brooks
|
NSTXU-CALC-11-04-00 =>
COMBINED WITH
CALC-11-03
|
|
|
|
|
|
|
Armor
|
1001
|
Tresemer
|
NSTXU-CALC-11-05-00
|
Analysis of Armor
Stresses
|
YES - APPROVED
|
Stevenson
|
YES
|
|
|
OBD Row 2 High Z Tiles
|
|
Tresemer
|
NSTXU-CALC-11-06-00
|
Qualify
the OBD Row 2 High Z Tiles
|
YES - APPROVED
|
Brooks
|
YES
|
|
|
Halo Current Heating of IBDhs Thermal
Shims
|
|
Brooks
|
NSTXU-CALC-11-07-00
|
Assess heating of the IBDhs
Thermal Shims from a halo current strike.
|
|
Ciummo
|
|
|
|
12- Vacuum Vessel
|
|
|
|
|
|
|
|
|
|
Disruption Analysis of VV &
Passive Plates
|
1002
|
Titus, et al
|
NSTXU-CALC-12-01-01
|
Disruption Analysis Of Vacuum Vessel
|
YES - APPROVED
|
Zhai
|
YES
|
ptitus-64lt1.pppl.gov
|
c:\nstx\csu\pp c:\nstx\csu\passivePlates
|
Dome/PF Stresses
|
1200
|
Titus
|
NSTXU-CALC-12-02-00
=> DELETED. PART OF
CALC-12-07
|
|
|
|
|
|
|
Opera 2D Analysis
|
1202
|
Hatcher
|
NSTXU-CALC-12-03-00
|
Using the 2D results
to drive 3D analysis
|
YES -
APPROVED
|
Brooks
|
YES
|
|
|
PF2 & PF3
Bolting, Bracket, & Weld Stress
|
1203
|
Titus
|
NSTXU-CALC-12-04-00
|
Analysis of PF2 &
PF3 Bolts, Brackets, & Weld Stresses
|
YES - APPROVED
|
Zatz
|
YES
|
ptitus-64lt1.pppl.gov
|
c:\nstx\csu\pf2_3
|
PF4 & PF5 Support
Analysis
|
1208
|
Titus
|
NSTXU-CALC-12-05-00
NSTXU-CALC-12-05-01
NSTXU-CALC-12-05-02
Draft
|
PF4 & PF5
Supports Stress Analysis
|
YES - APPROVED
|
Zatz
|
*
|
ptitus-64lt1.pppl.gov
|
c:\nstx\csu\PF45Sup
|
Aluminum Block
Analysis
|
1204
|
Titus
|
NSTXU-CALC-12-06-00
|
Qualify the Aluminum Block
Bolting for upgrades and modifications proposed for the NSTX CS Upgrade
|
YES - APPROVED
|
Zatz
|
*
|
ptitus-64lt1.pppl.gov
|
c:\nstx\csu\PF45Sup
|
Umbrella
Reinforcement Details
|
1205
|
Zhang
|
NSTXU-CALC-12-07-00
NSTXU-CALC-12-07-01
|
The purpose of this
calculation is to qualify the umbrella structure for increased loads and
needed modifications for the NSTX CS Upgrade
|
YES - APPROVED
|
Zatz
|
*
|
ptitus-64lt1.pppl.gov
|
c:\nstx\csu\dome
|
Lid & Spoke
Assembly, Upper & Lower
|
1205
|
Titus/Smith
|
NSTXU-CALC-12-08-01
NSTXU-CALC-12-08-02
|
The purpose of this
calculation is to qualify the upper and lower lid assemblies.
|
YES - APPROVED
|
Zatz
|
*
|
ptitus-64lt1.pppl.gov
|
c:\nstx\csu\lidflex
|
Pedestal Analysis
|
1205
|
Titus/Smith
|
NSTXU-CALC-12-09-00
NSTXU-CALC-12-09-01
|
The purpose of this calculation is to qualify the
stresses in Pedestal support for the centerstack
assembly. Additionally, the effect of the torsional stiffness of the
pedestal will be assessed.
|
YES - APPROVED
|
Zolfaghari
Zhang
|
YES
|
ptitus-64lt1.pppl.gov
|
c:\nstx\csu\pedestal
|
Redesigned Vessel
Support Bracket
|
1677
|
Rogoff
|
NSTXU-CALC-12-10-00
NSTXU-CALC-12-10-01
|
The
purpose of this calculation is to evaluate the redesigned vessel support
Bracket
|
YES - APPROVED
|
Zatz
|
YES
|
|
|
Center Stack Upgrade
|
1200
|
Zhai
|
NSTXU-CALC-12-11-00
|
Analysis of Secondary Passive Plate with Diagnostic cutout
|
YES - APPROVED
|
Titus
|
YES
|
smith-64pc.pppl.gov
|
c:\nstx\ansys\ansys models
c:\nstx\opera models
|
RWM Coil Analysis
|
4501
|
Titus
|
NSTXU-CALC-12-12-00
|
The purpose of this calculation
is to qualify the Resistive Wall Mode (RWM) Coils for Upgrade Loads and new
current made possible by the addition of new SPA power supplies.
|
YES - APPROVED
|
Woolley/
Heitzenroeder
|
YES
|
ptitus-64lt1.pppl.gov
|
|
|
|
|
|
|
|
|
|
|
|
13 - Magnets
|
|
|
|
|
|
|
|
|
|
130- General
|
|
|
|
|
|
|
|
|
|
Global Model -
Description, Mesh Generation, and Results
|
|
|
NSTX-CALC-13-01-01
=> Relabeled to
NSTXU-CALC-10-01-02 above
|
|
|
|
|
|
|
Maximum and Minimum Loads on the NSTX OH and PF Coils, and Coil
Groupings
|
|
|
NSTX-CALC-13-02-00
=> (Relabeled to
NSTXU-CALC-10-01-02 above
|
|
|
|
|
|
|
NSTX Force Influence
Matrix
|
1511
|
Hatcher
|
NSTXU-CALC-13-03-01
|
Updated NSTX Force
Influence Matrix
|
YES - APPROVED
|
Titus
|
YES
|
|
|
DCPS TF Inner Leg
Torsional Shear Stress
|
5200
|
Woolley & Titus
|
NSTXU-CALC-13-04-00
=> SUPERSEDED
BY CALC-132-07-00
|
|
|
|
|
|
|
DCPS Moment Influence
Coefficients
|
5200
|
Woolley & Titus
|
NSTXU-CALC-13-05-00
|
Calculation of
the moment influence coefficients to be applied to the PF currents
|
YES - APPROVED
|
Hatcher
|
YES
|
ptitus-64lt1.pppl.gov
|
c:\nstx\csu\momentCoefficients
|
Title
|
5200
|
Woolley
|
NSTXU-CALC-13-06-00
|
|
|
|
|
|
|
DCPS Check
Calculations
|
|
Titus
|
NSTXU-CALC-13-07-00
DRAFT
|
This
calculation either provides pointers to the appropriate calculation or
includes additional algorithm calculations here. The algorithms have been
incorporated into a True Basis code that can run the algorithm evaluations
for the 96 GRD design point equilibria and other provided scenarios. This
can be used to check the DCPS implementation or find limiting equilibria
among the provided 96.
|
|
Stevenson
|
|
|
|
131 -
Poloidal Field Coils
|
|
|
|
|
|
|
|
|
|
Analysis of NSTXU Poloidal Field
Coils (June 26, 2009 design)
|
|
Woolley
|
NSTXU-CALC-131-01-00 =>
SUPERSEDED BY CALC-131-03-00
|
|
|
|
|
|
|
Poloidal Magnetic
Quantities for the February 2010 Provisional Design of the NSTX CS
Upgrade
|
|
Woolley
|
NSTXU-CALC-131-01-00 =>
SUPERSEDED BY CALC-131-03-00
|
|
|
|
|
|
|
Poloidal Magnetic
Quantities for the May 2010 Provisional Design
|
|
Woolley
|
NSTXU-CALC-131-03-00
|
Update of the analysis of
poloidal magnetic fields and fluxes in (NSTXU CSU)
|
YES - APPROVED
|
Titus & Hatcher
|
YES
|
|
|
Qualification of friction
clamp to grip copper bar during PF1A winding setup
|
|
Mardenfeld
|
NSTXU-CALC-131-04-00
|
This calculation qualifies
the use of a friction clamp to grip a copper bar and apply load during
testing of winding equipment during setup for PF1A coil winding
|
YES
|
Sibilia
|
|
|
|
132 - Toroidal Field
Coils
|
|
|
|
|
|
|
|
|
|
Coupled Electromagnetic-Thermal Diffusion Analysis
|
|
Titus
|
NSTXU-CALC-132-01-00
=> SUPERSEDED
BY CALC-132-05-00
|
|
|
|
|
|
|
Coupled Electromagnetic-Thermal Analysis
(04202009)
|
|
Titus
|
NSTXU-CALC-132-02-00
=> SUPERSEDED
BY CALC-132-05-00
|
|
|
|
|
|
|
Out-Of-Plane (OOP) PF/TF Torques on TF
Conductors in NSTX NSTXU
|
|
Woolley
|
NSTXU-CALC-132-03-00
NSTXU-CALC-132-03-01
|
Also Includes:
- Torque Equations for the Design Point
|
YES -
APPROVED
|
Titus
|
YES
|
|
|
Analysis of
TF Outer Leg
|
|
Zhang
|
NSTXU-CALC-132-04-01
|
Analysis of TF Outer Leg:
- Loads
at Knuckle Clevis
- Loads
& Moments on Ring
- Outer
Leg Insulation Bond Stress
- Umbrella
Reinforcement
|
YES -
APPROVED
|
Zatz
|
*
|
hzhang-pc.pppl.gov
|
I:\NSTX_diamondbracing\V26_VVbuckling
|
TF Coupled Thermo
Electromagnetic Diffusion Analysis
|
|
Zhang
|
NSTXU-CALC-132-05-01
NSTXU-CALC-132-05-02
|
TF Coupled Thermo Electromagnetic
Diffusion Analysis
- Cooldown
of Flex
- Benchmark
of I^2t Calcs
- TF
Peak Temps at Corner
|
YES -
APPROVED
|
Zhai
|
YES
|
hzhang-pc.pppl.gov
|
I:\NSTX_TF_diffusion
|
TF Flex Joint and TF Bundle Stub
|
|
Willard
|
NSTXU-CALC-132-06-00
NSTXU-CALC-132-06-01
|
TF Flex Joint and TF
Bundle Stub
Will include:
- Joint Electrical Contact Resistance
- Flex Stress for Inplane
and OOP Loads
- DLF for Disruption
|
YES -
APPROVED
|
Zolfaghari
|
YES
|
|
|
Maximum TF Torsional Shear
|
|
Titus
|
NSTXU-CALC-132-07-00
NSTXU-CALC-132-07-01
|
Maximum TF Torsional
Shear
|
YES - APPROVED
|
Woolley
|
YES
|
ptitus-64lt1.pppl.gov
|
c:\nstx\csu\TFInnerLegTorque
|
TF Flag
Key
|
1304
|
Zolfaghari
Titus
|
NSTXU-CALC-132-08-01
NSTXU-CALC-132-08-02
|
Determination of
shear Forces Between the TF conductors and Insulation
and the G-10 Insulating Crown.
- TF Teeth & Collar Stresses
|
YES - APPROVED
|
Willard
Zolfaghari
|
YES
|
azolfag-64pc.pppl.gov
|
D:\NSTX\COIL\Magnetics & Structural\Center-stack-torque
|
Analysis of Knuckle
Clevis
|
1201
|
Titus
|
NSTXU-CALC-132-09-01
|
Analysis of stresses
on knuckle clevis
|
YES - APPROVED
|
Zhang
|
*
|
ptitus-64lt1.pppl.gov
|
c:\nstx\csu\TFClevis
|
TF Cooldown Using FCOOL
|
1201
|
Zolfaghari
|
NSTXU-CALC-132-10-00
NSTXU-CALC-132-10-01
|
Estimate of the
cooling time and temperature of the TF inner leg during the cooling period
between discharges
|
YES - APPROVED
|
Kalish
|
YES
|
azolfag-64PC.pppl.gov
|
C:\Users\azolfagh\Documents\fcool-program\NSTX-TF-Inner-Leg-Cooling
|
Ring Bolted Joint
|
1201
|
Rogoff
|
NSTXU-CALC-132-11-00
|
This analysis is performed in order to check and design the
joint integrity by selecting and specifying the necessary bolts
|
YES - APPROVED
|
Zatz
|
YES
|
p:\public\snp-srv\progoff\
|
NSTXU-CALC-132-11-00LapJoint
|
TF Outer Leg Clamp Assembly
|
1201
|
Rogoff
|
NSTXU-CALC-132-12-00
|
This analysis is
performed in order to check and verify the design integrity by selecting
and specifying the necessary pins and support brackets .
|
YES - APPROVED
|
Zatz
|
*
|
|
|
TF Coil Inductance
|
1201
|
Neumeyer
|
NSTXU-CALC-132-13-00
|
This analysis provides the
inductance of the TF coils for the upgrade.
|
YES - APPROVED
|
Hatcher
|
YES
|
|
|
TF Strap Assembly Fingers
|
1304
|
Dudek
|
NSTXU-CALC-132-14-00
|
NSTXU TF leaad
flag extensions support brackets were originally modeled in CALC-132-06.
Results indicated parts needed to be more robust to withstand loads.
Geometry has been iterate and a new calc to
document results
|
YES - APPROVED
|
Titus
|
YES
|
|
|
TF Lead Flag Extensions &
Connectors
|
1304
|
Titus
|
NSTXU-CALC-132-15-00
NSTXU-CALC-132-15-01
Draft
|
This calculation is to qualify
the TF lead flag extensions as part of a larger calc
NSTXU-CALC-132-06-00
|
YES - APPROVED
|
Zatz
|
YES
|
|
|
133 - Center Stack
|
|
|
|
|
|
|
|
|
|
Structural
Analysis of the PF1 Coils & Supports
|
1306
|
Myatt
Zolfaghari
|
NSTXU-CALC-133-01-01
NSTXU-CALC-133-01-02
|
Structural
Analysis of the PF1 Coils & Supports
|
YES - APPROVED
|
Brooks & Zolfaghari
Titus
|
YES
|
azolfagh-64pc1.pppl.gov
|
C:\NSTX\COIL\mag & struc\internal
PFs
|
Thermal Stresses on
OH-TF Coils
|
|
Avasarala
|
NSTXU-CALC-133-02-00
=> SUPERSEDED
BY CALC-133-08-00
|
|
|
|
|
|
|
Center Stack Casing
Disruption Inductive and Halo Current Loads
|
1307
|
Titus
|
NSTXU-CALC-133-03-00
|
Centerstack Casing and Lower Skirt Stress Summary
|
YES - APPROVED
|
Brooks & Zolfaghari
|
YES
|
ptitus-64lt1.pppl.gov
|
c:\nstx\csu\case
|
OH Preload System
& Belleville Spring Design
|
1302
|
Rogoff
|
NSTXU-CALC-133-04-00
* Note: P Titus signed calc in place of
J. Chrzanowski
|
OH Preload System and Bellville
Spring Design
|
YES -
APPROVED
|
Kozub via Test
|
YES
|
p:\public\snp-srv\progoff\
|
NSTXU-CALC-133-04-00 Belleville
|
Halo Current Analyses of Center Stack Casing
|
1307
|
Brooks
|
NSTXU-CALC-133-05-00
NSTXU-CALC-133-05-01
|
Calculate the transient halo current distribution in the CS
|
YES - APPROVED
|
Titus
|
YES
|
abrooks-64pc1.pppl.gov
|
L:\ANSYS2\NSTX CSU\CS Halo\cshalo02r5
|
OH Coolant Hole
Optimization
|
1305
|
Zolfaghari
|
NSTXU-CALC-133-06-00
|
Estimate the
temperature rise in the OH coil during the discharge and to estimate
cooling time between discharges
|
YES -
APPROVED
|
Mardenfeld
|
YES
|
azolfag-64PC.pppl.gov
|
C:\Users\azolfagh\Documents\fcool-program\NSTX-OH
|
OH Coax Lead Analysis
|
1305
|
Mardenfeld
|
NSTXU-CALC-133-07-00
Addendum
|
Qualify those components providing an electrical path between
the bus bars and the main body of the OH coil, i.e., the coaxial cable,
electrical connectors, and embedded coil leads.
|
YES - APPROVED
|
Zolfaghari
|
YES
|
C:\Users\azolfagh\Documents\fcool-program\NSTX-OH
|
E:\mardenfeld\04 NSTX Upgrade OH Coil\Ansys
|
OH Stress Analysis
|
1305
|
Zolfaghari
|
NSTXU-CALC-133-08-00
NSTXU-CALC-133-08-01
|
|
YES - APPROVED
|
Mardenfeld
|
YES
|
azolfag-64PC.pppl.gov
|
D:\NSTX\COIL\Magnetics &
Structural\Axisymmetric-plane-coil-details\ANSYS-Analysisnetics
& Structural\Axisymmetric-plane-coil-details\ANSYS-Analysis…..
|
OH Fatigue &
Fracture Mechanics
|
1305
|
Feng & Titus
|
NSTXU-CALC-133-09-00
|
OH Conductor Fatigue and Fracture Mechanics Analyses
|
YES - APPROVED
|
Zatz
|
YES
|
|
|
Center Stack Casing
Bellows
|
1307
|
Rogoff & Brooks
|
NSTXU-CALC-133-10-00
|
·
CS Casing Halo Inductive & Resistive
Loads
·
CS Casing Static & Dynamic Loads
|
YES - APPROVED
|
Zatz
|
YES
|
p:\public\snp-srv\progoff\
|
NSTXU-CALC-133-10-00Bellows
|
OH & PF1 Electromagnetic Stability Analysis
|
1307
|
Titus & Zolfaghari
|
NSTXU-CALC-133-11-00
|
Demonstrate that the structural
elements that center the centerstack are stiff
enough to overcome magnetic instabilites between
the OH and PF1a, and b which are mounted on the centerstack
casing
|
YES - APPROVED
|
Zolfaghari
|
YES
|
ptitus-64lt1.pppl.gov
azolfag-64PC.pppl.gov
|
\nstx\csu\magstab
C:\Users\azolfagh\Documents\Ansoft
|
Center Stack
Manufacturing Fixture
|
|
|
NSTXU-CALC-133-12-00
|
|
|
|
|
|
|
Modal Analysis and Normal
Operation Transient Load Effects
|
|
Titus
|
NSTXU-CALC-133-13-00
|
Ensure that the normal operational
transients do not introduce structural dynamic effects that could increase
the static loading in evaluations being used for the coils and global
structure.
|
YES - APPROVED
|
Dahlgren
|
YES
|
ptitus-64lt1.pppl.gov
|
\nstx\csu\magstab
|
OH Stress and Segmented OH
Influence Coefficients for the DCPS
|
|
Titus
|
NSTXU-CALC-133-14-00
|
This document is a calculation
of stress influence coefficients for the mid height of the OH and those
needed to address the PF1a-OH interaction
|
YES - APPROVED
|
Gerhardt/
Zolfaghari/
Wooley
|
YES
|
ptitus-64lt1.pppl.gov
|
\nstx\csu\axisym\OHPF1aInteraction
|
Analysis of the PF1C
mandrel/Case CHI Gap thermal response including thermal shield design
|
|
Titus
|
NSTXU-CALC-133-15-00
|
The purpose of this calculation
is to provide guidance on initial design and qualification of the PF1c
outer mandrel shell.
|
YES - APPROVED
|
Zatz
|
YES
|
|
|
NSTXU OH-TF Aquapour
Interaction
|
|
Titus/Brooks/
Zhang
|
NSTXU-CALC-133-16-00
|
The
purpose of this calculation is to assess effects of retaining the Aquapour material in what was to be a gap between the
TF and OH coils.
|
YES - APPROVED
|
Zatz/Titus
|
YES
|
|
|
NSTXU OH Cooldown System and
Preheater
|
|
Titus
|
NSTXU-CALC-133-17-00
|
The purpose of this calculation
is to provide guidance on initial design and qualification of the final OH
Cooldown System. This includes the coil winding pack thermal stresses for
the original cooldown temperature sequence – which was essentially a thermal
shock, and for a new ramped thermal profile that mitigates the consequence
of extreme thermal gradients.
|
YES - APPROVED
|
Various
|
YES
|
|
|
PF1a Upper and Lower Replacement
Stress Analysis
|
|
Titus
|
NSTXU-CALC-133-18-00
|
The first purpose of this
calculation is to qualify the design of the new (Fall 2016) PF1a coil
design This will include assessments of the normal pulse loading, cooldown
behavior and the qualification tests. Additionally this calculation
includes evaluations of possible causes of the failure of PF1a upper. The
coil postmortem should provide a definitive conclusion as to the cause.
|
DRAFT
|
|
|
|
|
Re-orienting
the NSTXU CS Casing from horizontal to vertical or visa
versa
|
|
Mardenfeld
|
NSTXU-CALC-133-19-00
|
This calculation qualifies that
reorienting the NSTX-U CS Casing from Horizontal to Vertical, or visa versa, will not overstress
the tiles due to imposed displacements from
net beam bending behavior of the Casing.
|
|
|
|
|
|
OH
grounding strap and CS Casing Copper Cooling Tube Evaluations
|
|
Brooks
|
NSTXU-CALC-133-20-00
|
The
purpose of this calculation is to evaluate currents induced in the OH
ground strap as installed and as upgraded. Additionally induced currents in
the centerstack casing inner divertor
vertical section copper cooling tubes are calculated. These tubes have either failed under load, been crushed, or failed due to
corrosion.
|
DRAFT
|
|
|
|
|
TF
and OH Gap Electric Field Strength Distribution
|
|
Que
|
NSTXU-CALC-133-21-00
|
In
order to evaluate the “Aquapour” and four wires
effects to the TF and OH coil insulation system, the static electric field
analysis using Maxwell has been performed.
|
|
Brooks
|
|
|
|
2 - Plasma Heating
& Current Drive
|
|
|
|
|
|
|
|
|
|
Vessel Port Re-Work for NB
& Thomson Scattering Port
|
2480/4500
|
Willard
|
NSTXU-CALC-24-01-00
|
Includes:
- Neutral Beam Reinforcement
- Thomson Scattering Port
|
YES - APPROVED
|
Zolfaghari
|
YES
|
|
|
Armor Backing Plate
|
2460
|
Bryant
|
NSTXU-CALC-24-02-00
|
Includes:
- Disruption Loading
- Thermal Stress Analysis
|
YES - APPROVED
|
Zatz & Titus
|
YES
|
p:\public\snp-srv\bryant_Larry\
|
NEUTRAL BEAM ARMOR CALCULATION
|
HHFW Antenna
|
|
Zhang
|
NSTXU-CALC-24-03-01
|
Includes:
- Verification of the eddy current effect on antenna during
plasma disruption.
- Then was
modified to simulate plasma disruption case for NSTX upgrade. Only mid-plane
disruption is considered and VDE is not included.
|
YES - APPROVED
|
Hatcher
|
YES
|
hzhang-pc.pppl.gov
|
D:\HHFW
|
Turbo Pump Magnetic Shielding Analysis
|
2485
|
ZhaI
|
NSTXU-CALC-24-04-00
|
Includes 3D analysis
for the design opf the magnetic shield for the
NSTXU Turbor Pumps.
|
YES - APPROVED
|
Zolfaghari
|
YES
|
yzhai-64pc1.pppl.gov
|
E:\yzhai-64pc\C Drive\NSTX\Opera Models\Turbo Pump Shielding
|
Stress Analysis of
Bay L and 2nd NBI Upgrade
|
4500
|
Atnafu
|
NSTXU-CALC-24-05-00
|
To analyze the stress
on the NSTX vacuum vessel due to the vacuum pressure, the PF 4&5 Coils
EM loads and the moment caused by the TFOL Coils. To understand the
mechanical behavior and estimate the stress in the modified vacuum vessel.
To validate the design of the bay L and 2nd Neutral Beam
modifications
|
YES - APPROVED
|
Zhang
|
YES
|
|
|
S-FLIP Port Stress
Analysis
|
2480
|
Zhang
|
NSTXU-CALC-24-06-00
|
To analyze the stress
on the S-FLIP port added to the vessel at the midplane
between Bays J and I.
|
YES - APPROVED
|
Titus
|
YES
|
hzhang-pc.pppl.gov
|
I:\NSTX_baKJ_cap
|
|
|
|
|
|
|
|
|
|
|
3 - Auxiliary Systems
|
|
|
|
|
|
|
|
|
|
This
calculation determines the ohmic resistance of
the NSTX CSU center stack casing, and therequirements
for a power supply capable of supplying 5kW of heat to same during bakeout.
|
3300
|
Dudek
|
NSTXU-CALC-33-01-00
|
During bakeout a current shall be injected at the bottom of
the center stack casing (CSC) which shall flow up through the center stack
casing, through four jumpers to the outer vacuum vessel (VV) upper dome,
down through the VV dome to the cylinder, down through the VV cylinder,
down through the lower VV dome, and out.
|
YES - APPROVED
|
Ramakrishnan
|
YES
|
|
|
|
|
|
|
|
|
|
|
|
|
4 - Plasma
Diagnostics
|
|
|
|
|
|
|
|
|
|
Diagnostic Review & Database
|
2300
|
Boales
|
NSTXU-CALC-40-01-00
|
Surveyed the existing NSTX diagnostics
and identified any components that would be sensitive to the increased
thermal and electromagnetic loading
planned for the upgrade. Also qualified the diagnostics and diagnostic
shutters for any larger disruption loads, heat loads, and any other factors
that may present a problem to the function of the
diagnostic systems.
|
YES - APPROVED (Note: R. Kaita signature needs to be
updated)
|
Zhai
|
YES
|
|
|
EM forces on BES
Reentrant Tube Assembly
|
4100
|
Brooks
|
NSTXU-CALC-40-02-00
|
Calculate the EM loads on the BES
Reentrant Tube Assembly during a plasma disruption.
|
YES - APPROVED
|
Titus
|
YES
|
|
|
Resistive
Bolometer/AXUV Diode Shutter Bowing
|
4100
|
Ellis
|
NSTXU-CALC-40-03-00
|
The purpose of this calculation is to
evaluate shutter deformations when exposed to radiative heating from the
plasma for a full 5 second pulse.
|
YES - APPROVED
|
Titus
|
YES
|
|
|
Resistive Bolometer
Disruption Load Analysis
|
|
Zhang
|
NSTXU-CALC-40-04-00
|
The purpose of this calculation is to
evaluate the disruption load and stresses on the flange.
|
|
Titus
|
|
|
|
5 - Power Systems
|
|
|
|
|
|
|
|
|
|
Modification of the
TF Coil Power System PSCAD Model
|
5000
|
Nayak
Corporation
|
NSTXU-CALC-53-01-00
|
Evaluates the change
in the TF circuits from four parallels to eight parallels to meet the upgrade
requirement of 130kA
|
YES - APPROVED
|
Que
|
YES
|
|
|
Modification of the
OH Coil Power System PSCAD Model
|
5000
|
Nayak
Corporation
|
NSTXU-CALC-53-02-00
|
Evaluates the change
in the TF circuits from four parallelsto eight
parallels to meet the upgrade requirement of 130kA
|
YES - APPROVED
|
Que
|
YES
|
|
|
TF Cabling from the
Transition Area to NSTXU Test Cell
|
5000
|
Neumeyer
|
NSTXU-CALC-53-03-00
|
The TF circuit is to be changed from four parallels to eight
parallels to meet the upgrade requirement of 130kA. Eight 1/c-1000 mcm
cables are proposed to be used in each leg of the TF circuit for the run
from Transition Area to the NSTX
Test Cell.
|
YES - APPROVED
|
Ramakrishnan
|
YES
|
|
|
TF Cabling from the
Rectifiers to SDS
|
5000
|
Neumeyer
|
NSTXU-CALC-53-04-00
|
The TF circuit is to be changed from four parallels to eight
parallels to meet the upgrade requirement of 130kA. Three 1/c-750 mcm
cables are proposed to be used per pole in FOUR power supply branches of
the TF circuit for the run from the Rectifiers to the Safety Disconnect
Switches.
|
YES - APPROVED
|
Ramakrishnan
|
YES
|
|
|
Current Unbalance in
the Eight Parallel Branches s
|
1540
|
Ramakrishnan
|
NSTXU-CALC-53-05-00
|
To
determine the current unbalance in the eight parallel branches if a common
firing angle command is issued to all rectifiers.
|
YES - APPROVED
|
Hatcher
|
YES
|
|
|
CHI Bus Bar Analysis
|
5501
|
Titus
|
NSTXU-CALC-54-01-00
|
CHI Bus Bar Analysis
|
YES - APPROVED
|
Khodak
|
YES
|
ptitus-64lt1.pppl.gov
p:\departments\mech Engr\ptitus
|
c:\nstx\csu\chibus
|
Bus Bar Analysis
|
5501
|
Khodak
|
NSTXU-CALC-55-01-00
NSTXU-CALC-55-01-01
NSTXU-CALC-55-01-02
|
Documented Structural Analysis
of PF1, TF, and OH bus bars
|
YES - APPROVED
|
Titus
|
YES
|
|
|
Bus Bar Analysis
|
5501
|
Titus
|
NSTXU-CALC-55-02-01
|
PF 2,3 Bus Bar Analysis
|
YES - APPROVED
|
Khodak
|
YES
|
|
|
Lead and flex cable
reinforce
|
5501
|
Titus
|
NSTXU-CALC-55-03-00
|
PF1A Lead and Flex Cable
Reinforcements
|
YES - APPROVED
|
Khodak, Zatz, Mardenfeld, Zolfaghari
|
YES
|
|
|
6 - Central I&C
Systems
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7 - Project
Management & Physics
|
|
|
|
|
|
|
|
|
|
71 - Project Mgmt & Integration
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
72 - Project Physics
|
|
|
|
|
|
|
|
|
|