Notes
from 3/10 Meeting:
Titus (see
VGs)
The torsional moment for
design of the lid/flex/Diaphragm bolting and the TF steps or keys is
0.3MN-m for the lower lid and 0.25 MN-m for the upper flex. This is the
torque being transmitted from the centerstack TF to the outer rim of the
umbrella structure.
Provided analysis
on PF4,5 Stress with 12 Support Points and Thermal Loads. The
conductor loads appear to be modest. Mangra noted that the model doesn't
yet reflect the planned compliance in the radial direction which should improve
the stresses further. Action: Mangra to provide compliance layer spec
information for analysis.
Chrzanowski (see
VGs)
Presented the plans for
R&D. The major elements include fatigue strength test on the flex
joint material, formability and stiffness tests and cyclic testing.
Friction stir welding and taplock pullout testing is also planned.
The mockup of a two coil
inner to OTF flex connection is in the shop for fabrication. The mockup
will demonstrate access to bolt up the inner TF to flex strap.
For the FDR additional
testing on the Flex strap assembly is planned as well as testing of the assembly
tools for the flex joint connection.
Mangra (see
VGs)
Presented his understanding of the requirements for
the umbrella lids and pedestal and solicited comments.
Viewgraphs will be posted by B.
Simmons